hellllo,
i did some tests with the Digital-IO from Wiesemann & Theis and IO (Devices Wiesemann+Theis Digital-EA).
while the node works fine, when enabling it first, it seems, that the socket doesn’t get closed properly, when disabling.
so, when disabling and enabling the node, i get some errors in the TTY:
00:20:48 - : TMWutDigitalEA interface timeout - reconnecting
00:20:49 - : TMWutDigitalEA Connecting
00:20:50 - : TMWutDigitalEA Socket Connect Error 10061 192.168.100.201:49153
00:20:58 - : TMWutDigitalEA interface timeout - disconnecting
00:20:58 - : TMWutDigitalEA Disconnect
and so on…
error code 10061 is described here: http://msdn.microsoft.com/en-us/library/windows/desktop/ms740668(v=vs.85).aspx
then i made a plugin (attached) to have a look at the computers open tcp-connections (like netstat) and found out, that the socket remains open and the connection stays established.
unfortunately IO (Devices Wiesemann+Theis Digital-EA) is not part of the addonpack (and probably coded in delphi), so i can’t fix that by myself.
perhaps, the nodes author(s) have an idea or are willing to opensource the code?
thanks,
sebl
ConnectionInfo (Network).7z (6.3 kB)